[2025] Pass H19-402_V1.0 Exam - Real Questions & Answers [Q278-Q301]

Share

[2025] Pass H19-402_V1.0 Exam - Real Questions and Answers

H19-402_V1.0 Exam Questions Get Updated [2025] with Correct Answers


Huawei H19-402_V1.0 (HCSP-Presales-Data Center Network Planning and Design V1.0) Exam is a certification exam offered by Huawei for individuals who want to become proficient in planning and designing data center networks. H19-402_V1.0 exam is designed to test the knowledge and skills required to design and implement data center network solutions using Huawei products and technologies. H19-402_V1.0 exam is intended for professionals who work in the presales or technical support roles in the IT industry.


Huawei H19-402_V1.0 certification exam is a globally recognized certification that demonstrates an individual's expertise in data center network planning and design using Huawei technologies. Certified professionals will be able to work with a broad range of Huawei products and technologies, which will enable them to design and implement highly efficient and secure data center networks. Overall, the Huawei H19-402_V1.0 certification exam is an excellent choice for IT professionals who are looking to validate their skills and knowledge in data center network planning and design.

 

NEW QUESTION # 278
What are the column-wrapping scenarios of FM2000? (Multiple choice)

  • A. Columns at both ends of the cabinet
  • B. Pillars in the channel
  • C. Column in the cabinet
  • D. Columns spanning cabinets and aisles

Answer: A,B,C,D


NEW QUESTION # 279
Which of the following is the refrigerant type of Huawei NetCol row-level air-cooling air conditioner?

  • A. R22`
  • B. None
  • C. R410A
  • D. Freon

Answer: C


NEW QUESTION # 280
Which of the following air conditioning systems requires a cooling tower or dry cooler?

  • A. DX water-cooled type
  • B. Direct ventilation air conditioning system
  • C. DX air-cooled type
  • D. CW air-cooled type

Answer: A


NEW QUESTION # 281
What is the static load of the FusionModule200 cabinet?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: A


NEW QUESTION # 282
Which of the following models can be equipped with an external large-capacity battery charger for fast recharging?

  • A. UPS5000-E
  • B. UPS2000-A6/10K Professional Edition Standard
  • C. UPS2000-G6K long-term
  • D. UPS5000-A

Answer: B


NEW QUESTION # 283
The domestic power supply standard is 380v/50Hz.

  • A. False
  • B. True

Answer: A


NEW QUESTION # 284
Among the following options, which of the following is the correct statement about the reliability of UPS5000-A (30kVA~120kVA)? (Multiple choice)

  • A. Ultra-wide input voltage range
  • B. The inverter has strong overload capacity
  • C. 6kV/5kA lightning protection design
  • D. Conformal coating technology

Answer: A,B,C,D


NEW QUESTION # 285
What aspects of FusionModule800 require on-site survey? (Multiple choice)

  • A. Wiring method
  • B. Pipe routing
  • C. Length between inner and outer units
  • D. Length of the cable from AC to module

Answer: A,B,C,D


NEW QUESTION # 286
UPS2000-G is an online double-conversion UPS. In normal working conditions: energy is provided by the mains, the rectifier converts alternating current into direct current, and the inverter converts the rectified direct current into pure alternating current and supplies it to the load. The charger charges the battery pack.

  • A. False
  • B. True

Answer: B


NEW QUESTION # 287
What kind of inlet and outlet wiring methods can the FusionModule2000 integrated power distribution cabinet implement?

  • A. Lower inlet and upper outlet
  • B. Upper inlet and outlet
  • C. Up-line in and down-line out
  • D. Down-in and down-out

Answer: B


NEW QUESTION # 288
FusionModule1000AV2R3 version uses Huawei UPS5000E as IT load power supply.

  • A. False
  • B. True

Answer: A


NEW QUESTION # 289
UPS5000 -E only needs to be equipped with () to easily realize the N+X power supply system, which is simple and convenient to operate?

  • A. Parallel card
  • B. Parallel Cable
  • C. BSC cable
  • D. BSC control panel

Answer: B


NEW QUESTION # 290
What functions does the iCooling feature of FusionModule2000 V3.0 include? (Multiple choice)

  • A. Refrigeration system visualization
  • B. Temperature cloud map and air conditioning linkage
  • C. AI self-optimization algorithm, air conditioning energy saving 8%
  • D. Refrigerant capacity alarm function

Answer: A,B,C,D


NEW QUESTION # 291
In Fusionmodule2000, c system linkage strategy.

  • A. False
  • B. True

Answer: B


NEW QUESTION # 292
Huawei's air-cooled precision air conditioner refrigerant pipeline is limited. What derived product can solve this problem well?

  • A. Indirect evaporative cooling
  • B. Chilled water precision air conditioning
  • C. Water-cooled DX

Answer: C


NEW QUESTION # 293
Which of the following is incorrect about the function description of iMiManager in FusionModule2000v3.0?

  • A. All of the above
  • B. Support automatic asset configuration
  • C. Can display capacity data such as space, power distribution, and cooling
  • D. When the server is listed, the best server location can be recommended

Answer: A


NEW QUESTION # 294
What is the UPS2000-G 6-20k host operation interface? which can display the system status in real time.

  • A. Remote network management
  • B. Touch screen
  • C. LCD
  • D. LED

Answer: C


NEW QUESTION # 295
Huawei 25KW half cabinet variable frequency air-cooled air conditioner, which of the following description is correct? (Multiple choice)

  • A. The UPS capacity requirement for a single air conditioner is 79.0kVA. If UPS5000E is used, at least two 40kVA power modules are required.
  • B. If a group of air conditioners is connected to a UPS system, then the capacity requirement of a single UPS system should be multiplied by the number of air conditioners running simultaneously. For example, if there is a 5+1 cold backup configuration, the capacity requirement of a single air conditioner UPS system should be
  • C. The capacity calculation of a single air conditioner with UPS is 1.251.732 full load current 380*0.8/0.9
  • D. The capacity calculation of a single air conditioner with UPS is 1.21.732 full load current 3800.8/0.9
  • E. The UPS capacity requirement for a single air conditioner is 15.8kVA. If UPS5000E is used, at least one 25kVA power module is required.

Answer: B,D,E


NEW QUESTION # 296
The FusionModule2000 sensor uses PoE ring network power supply to improve the reliability of control system signal transmission and can be used to control standards.

  • A. False
  • B. True

Answer: B


NEW QUESTION # 297
NetCol8000-C room-level chilled water intelligent temperature control product has components that can be maintained online, which can greatly reduce the time for component replacement? (Multiple choice)

  • A. Auxiliary source module
  • B. Electric heating
  • C. Fan
  • D. Main control module

Answer: A,D


NEW QUESTION # 298
Huawei network management NetEco supports northbound SNMP protocol.

  • A. False
  • B. True

Answer: B


NEW QUESTION # 299
FusionModule800 has the function of automatic start-up of civil air conditioner when receiving a call

  • A. False
  • B. True

Answer: A


NEW QUESTION # 300
The modules used in UPS5000-E-75K half-height modular UPS are also 25k.

  • A. False
  • B. True

Answer: B


NEW QUESTION # 301
......